Brand Name : Air Giant

Model Number : QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2

Certification : CAL,CMA,CNAS,ILAC-MRA,CCC

Place of Origin : China

MOQ : 1 set

Price : negotiation

Payment Terms : L/C, D/P, T/T, Western Union, Paypal, Credit card

Supply Ability : 28000 sets per week

Delivery Time : 10-15 working days

Packaging Details : Plywood outer box with bubble bag or paper

Storage Pressure : 4.2MPa

Spraying Time : ≤10s

Filling Density : ≤1420kg/m3

Nominal Pressure : 5.3MPa

Test Pressure : 8.4MPa

Working Power : DC 24V 1.6A

Working Temperature : 0℃~50℃

Protected Zone Range : Proportion: ≤800m² Volume: ≤3600m³

Starting Mode : Automatic, Electrical Manual, Mechanical Manual

Cylinder Volume : 40L、70L、100L、120L、150L、180L

Contact Now

Cafss FK 5-1-12 fire suppression system without pollution for UPS room um

Perfluorohexadone automatic fire extinguishing system, also known as Novec1230 / FK-5-1-12 automatic fire extinguishing system, is a gas fire extinguishing system based on perfluorocarbons, which is used to extinguish dangerous chemicals and other flammable and explosive objects.

The perfluorohexadone automatic fire extinguishing system uses the colorless and odorless perfluorocarbon Novec1230 / FK-5-1-12 as the fire extinguishing agent, which has the following characteristics:

1. Environmental protection: Novec1230 / FK-5-1-12 is a non-toxic, colorless, tasteless, non-corrosive, non-conductive and non-explosive fire extinguishing agent, which can protect equipment and environment from damage.

2. High efficiency: the PFH automatic fire extinguishing system can extinguish the fire quickly in a short time without any damage to the protected equipment.

3. High safety: Novec1230 / FK-5-1-12 fire extinguishing agent has high stability, is not easy to burn, and will not produce harmful substances. Therefore, the use of this fire extinguishing system can effectively ensure the safety of personnel and equipment.

4. Strong flexibility: PFH automatic fire extinguishing system can flexibly adapt to different fire extinguishing requirements, and is applicable to various sizes and types of places.

The working principle of the PFH automatic fire extinguishing system is that when a fire occurs, the system detector detects the fire source, and the controller will automatically open the vent valve to release the Novec1230 /FK-5-1-12 fire extinguishing agent from the pipe network and enter the fire extinguishing area to extinguish the fire. The fire extinguishing system is an ideal fire extinguishing device with simple operation, high automation and fast and effective fire extinguishing.

Working Principle

The working principle of the PFH automatic fire extinguishing system is that when a fire occurs, the system detector detects the fire source, and the controller will automatically open the vent valve to release the Novec1230 /FK-5-1-12 fire extinguishing agent from the pipe network and enter the fire extinguishing area to extinguish the fire. The fire extinguishing system is an ideal fire extinguishing device with simple operation, high automation and fast and effective fire extinguishing.

Here is the illustration of working principle to whole system.

Cafss FK 5-1-12 Fire Suppression System Without Pollution For UPS Room

Components

1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing Novec1230 agent

2. Electrical parts: smoke detector, heat detector, bell etc.

3. Pipe fittings: conduit, connector, elbow, flange etc.

Cafss FK 5-1-12 Fire Suppression System Without Pollution For UPS Room

Application

As its name says, the single zone pipe network Novec1230 fire suppression system is suitable for a single protected zone, whose volume should be less than 3600 cubic meters as well as proportion should be less than 800 square meters. Because of its property and principles of putting off fire, the single zone pipe network Novec1230 fire suppression system can be used to protect some large and also significant places, such as the followings:

- Computer rooms

- Telecommunication center

- Facilities underground

- Offshore oil extraction

- Library

- Data and paper archives

- Valuable article storage

- Power generator storage room

Cafss FK 5-1-12 Fire Suppression System Without Pollution For UPS Room

Advantages

It is very efficient for you to protect your possession. Since it is a system, it includes extinguishing device to put out fire in a short time. It means all agent will be discharged in less than 10 seconds. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minutes. It means when a fire happens, there is enough time for people escaping the building. We have listed out two points for customer as reference.

1/ Flexible application in protection zones. As its structure and assembly of other useful components, it can concentrate one very big protection zone with the combination of multiple storage cylinders. Its coverage can be also very small with the system of a single cylinder.

2/ Combined distribution system. The most distinctive and flexible advantage of this system is combined distribution system, which will combine multiple rooms in one district or building but with different dimensions or in different floor. Meanwhile, it can reduce the cost based on the original by the least and safe utilization of fire extinguishing gas. Because of the adoption of selective valves that can guide the fire extinguishing gas into the room on fire, so it would be relatively smarter to monitor each room to avoid an accident. It is worthy to mention that the combined rooms should be less than 8 including 8 in accordance with our standard.

Packages

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

Cafss FK 5-1-12 Fire Suppression System Without Pollution For UPS Room


Product Tags:

UPS Room Fire Suppression System

      

Cafss FK 5-1-12 Fire Suppression System

      
Best Cafss FK 5-1-12 Fire Suppression System Without Pollution For UPS Room wholesale

Cafss FK 5-1-12 Fire Suppression System Without Pollution For UPS Room Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Air Giant Fire Equipment Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0